G657A2 Plus Bending Insensitive Single-mode Fiber
Application:
- Due to its outstanding performance in both attenuation and bending resistance, Feiboer Low Loss Bending Insensitive Single-mode Fibre is fully compatible with different cabling and differentiated systems in different installation environments of trunk network, metropolitan area network, access network and resident network.
Characteristics | Conditions | Specified values | Units | |
|---|---|---|---|---|
Optical Characteristics | ||||
| Attenuation | 1310nm | ≤0.35 | [dB/km] | |
1383nm(after H2-aging) | ≤0.35 | [dB/km] | ||
1460nm | ≤0.25 | [dB/km] | ||
1490nm | ≤0.23 | [dB/km] | ||
1550nm | ≤0.21 | [dB/km] | ||
1625nm | ≤0.23 | [dB/km] | ||
| Attenuation vs. Wavelength Max. α difference | 1285-1330nm, in reference to 1310nm | ≤0.03 | [dB/km] | |
1525-1575nm, in reference to 1550nm | ≤0.02 | [dB/km] | ||
Zero Dispersion Wavelength(λ0) | -- | 1300-1324 | [nm] | |
Zero Dispersion Slope(S0) | -- | ≤0.092 | [ps/(nm2·km)] | |
PMD | Maximum Individual Fibre | -- | ≤0.1 | [ps/√km] |
| Link Design Value(M=20,Q=0.01%) | -- | ≤0.06 | [ps/√km] | |
| Typical Value | -- | 0.04 | [ps/√km] | |
Cable Cutoff Wavelength (λCC) | -- | ≤1260 | [nm] | |
Mode Field Diameter(MFD) | 1310nm | 8.4-9.2 | [μm] | |
1550nm | 9.3-10.3 | [μm] | ||
Effective Group Index of Refraction(Neff) | 1310nm | 1.466 | -- | |
1550nm | 1.467 | -- | ||
Point Discontinuities | 1310nm | ≤0.05 | [dB] | |
1550nm | ≤0.05 | [dB] | ||
Geometrical Characteristics | ||||
Cladding Diameter | -- | 125.0±0.7 | [μm] | |
Cladding Non-Circularity | -- | ≤0.7 | [%] | |
Coating Diameter | -- | 235-245 | [μm] | |
Coating-Cladding Concentricity Error | -- | ≤12.0 | [μm] | |
Coating Non-Circularity | -- | ≤6.0 | [%] | |
Core-Cladding Concentricity Error | -- | ≤0.5 | [μm] | |
Curl(radius) | -- | ≥4 | [m] | |
Delivery Length | -- | Up to 50.4 | [km/reel] | |
Environmental Characteristics | 1310nm, 1550nm & 1625nm | |||
Temperature Dependence Induced Attenuation | -60℃ to +85℃ | ≤0.05 | [dB/km] | |
Temperature-Humidity Cycling Induced Attenuation | -10°C to +85°C, 98% RH | ≤0.05 | [dB/km] | |
Watersoak Dependence Induced Attenuation | 23°C, for 30 days | ≤0.05 | [dB/km] | |
Damp Heat Dependence Induced Attenuation | 85°C and 85% RH, for 30 days | ≤0.05 | [dB/km] | |
Dry Heat Aging | 85℃, for 30 days | ≤0.05 | [dB/km] | |
Mechanical Specification | ||||
| Proof Test | -- | ≥9.0 | [N] | |
-- | ≥1.0 | [%] | ||
-- | ≥100 | [kpsi] | ||
Macro-bend Induced Attenuation | 10 Turns Around a Mandrel of 15 mm Radius | 1550nm | ≤0.03 | [dB] |
| 10 Turns Around a Mandrel of 15 mm Radius | 1625nm | ≤0.1 | [dB] | |
| 1 Turn Around a Mandrel of 10 mm Radius | 1550nm | ≤0.1 | [dB] | |
| 1 Turn Around a Mandrel of 10 mm Radius | 1625nm | ≤0.2 | [dB] | |
| 1 Turn Around a Mandrel of 7.5 mm Radius | 1550nm | ≤0.5 | [dB] | |
| 1 Turn Around a Mandrel of 7.5 mm Radius | 1625nm | ≤1.0 | [dB] | |
Coating Strip Force | typical average force | 1.5 | [N] | |
peak force | 1.3-8.9 | [N] | ||
Dynamic Fatigue Parameter(nd) | -- | ≥20 | -- | |
Talk to our team today
We take pride in providing timely, reliable and useful services

Optical Fiber
ADSS Fiber Optic Cable
ASU Fiber Optic Cable
FTTH Fiber Optic Cable
Figure 8 Fiber Optic Cable
OPGW Fiber Optic Cable
Coaxial Cable
Ethernet Cable
Photoelectric Composite Fiber Optic Cable
Underground & Pipeline Fiber Optic Cable
Air-Blown Micro Fiber Optic Cable
Indoor Fiber Optic Cable
Fiber Optic Distribution Box
Multiport Service Termina Box
Fiber Optical Terminal Box
Fiber Optic Splice Closure
Fiber Optic Clamps
Fiber Optic Cable Fittings
ADSS Fiber Cable
ASU Fiber Cable
OPGW Fiber Cable
FTTH Fiber Cable
Figure 8 Fiber Cable
Photoelectric Composite Fiber Cable
Underground & Pipeline Fiber Cable
Air-Blown Micro Fiber Cable
Aerial Fiber Cable
Indoor Fiber Cable
Fiber Optical Terminal Box
Fiber Optic Distribution Box
Multiport Service Termina Box
Fiber Optic Clamps
About Us
Our Team
History
R&D Strength
Production Base
Warehouse & Logistics
Quality
FAQs